Data report · Medical devices and IVDs · 2026
Colombia Medical Device Registrations 2026: What INVIMA's Data Shows
We analyzed the 35,491 health registrations for medical devices and in vitro diagnostic reagents that INVIMA publishes as open data. What is active, where it is made, who holds it, how many get renewed and what expires over the next two years.
The essentials
Key findings
- 0114,005medical device registrations are active, plus 6,656 for in vitro diagnostic reagents.1See it
- 0231%of active devices are high risk (class IIb and III); the most common class is IIa, at 40%.1See it
- 0327.2%of active device registrations list a manufacturer in China. The US appears in 23.7%.1See it
- 049 in 10device registrations are for imported products. For IVD reagents, 98%.1See it
- 0530%of device registrations are held by a company domiciled outside Colombia.1See it
- 0610%of active devices belong to the ten largest holders, out of 3,000 distinct holders.1See it
- 072,240device registrations and 1,692 IVD registrations expire within the next 24 months.1See it
- 0828.5%of device registrations that expired between 2021 and 2025 were renewed (estimate). For class III, 51.9%.1See it
- 091,229new device registrations in 2026 as of October 27, almost as many as in all of 2025 (1,241).1See it
Chapter 1 of 9
The active registry: 20,661 registrations
INVIMA publishes 35,491 health registrations for medical devices and in vitro diagnostic reagents as open data. As of October 27, 2026, 20,661 are active: 14,005 for medical devices and 6,656 for reagents. The rest no longer allow the product to be sold or are in process: 10,190 expired, 1,435 cancelled, 1,229 that lost legal effect, 317 under renewal and 133 suspended.1
Active medical device registrations by risk class
Number of active registrations as of October 27, 2026.
Almost seven in ten registered devices are low or moderate risk (class I or IIa).
See the data
| Active registrations | |
|---|---|
| Class I | 4,058 |
| Class IIa | 5,590 |
| Class IIb | 2,219 |
| Class III | 2,138 |
The risk class sets how much INVIMA requires to approve a registration, not how long it lasts: every device registration is valid for 10 years. We explain each class in our guide to medical device risk classification in Colombia.
Active in vitro diagnostic reagent registrations by category
Number of active registrations as of October 27, 2026. 456 registrations carry no category in the dataset.
Half of active reagents are category II, and one in three is category III, the highest risk.
See the data
| Active registrations | |
|---|---|
| Category I | 695 |
| Category II | 3,279 |
| Category III | 2,226 |
| No category in the data | 456 |
Chapter 2 of 9
Where devices are made: China has overtaken the US
Each registration lists one or more manufacturers, with their country. We count a registration once for each country among its manufacturers, so the percentages can add up to more than 100%. Active device registrations involve 8,360 manufacturers from 88 countries.1
Country of manufacturer in active device registrations
Share of the 14,005 active registrations with at least one manufacturer in each country. Top ten countries.
China appears as manufacturer on more active device registrations than the US: 3,810 against 3,313.
See the data
| Active registrations | |
|---|---|
| China | 27.2% |
| United States | 23.7% |
| Colombia | 10.7% |
| Germany | 8.7% |
| Mexico | 4.5% |
| Brazil | 4.1% |
| France | 3.6% |
| Switzerland | 3.2% |
| India | 3.1% |
| Italy | 3.1% |
Country of manufacturer in active reagent registrations
Share of the 6,656 active registrations with at least one manufacturer in each country. Top eight countries.
In reagents the US leads, with almost one in three registrations. Colombia appears as manufacturer in just 1.9%.
See the data
| Active registrations | |
|---|---|
| United States | 31.9% |
| Germany | 18.2% |
| China | 18.0% |
| Spain | 7.1% |
| United Kingdom | 6.9% |
| France | 5.3% |
| Ireland | 5.2% |
| Italy | 4.6% |
Chapter 3 of 9
Nine in ten registrations are for imported products
- 90.0%
- of active device registrations are to import and sell
- 98.2%
- of active reagent registrations are to import and sell
- 30.3%
- of device registrations have a holder domiciled abroad
- 2,867
- distinct importers appear in active device registrations
This report counts registrations, not dollars. Measured by value, ProColombia estimates imports covered 77% of the device market in 2025 (see our Colombia medical device market brief).3 By number of registrations the share rises to 90%: almost everything registered for sale in Colombia is made abroad.1
4,246 active device registrations are held by a company domiciled outside Colombia. A foreign manufacturer can hold its own registration and rely on a local importer to bring the product in, a setup we explain in our guide to medical device companies in Colombia.1
Chapter 4 of 9
Who holds the registrations: a fragmented market
The 14,005 active device registrations belong to 3,000 distinct holders, and 1,467 of them hold a single registration. The ten largest holders add up to 10.2% of the total. Reagents are the opposite: 331 holders, with the top ten holding 48.7%.1
The ten holders with the most active device registrations
Number of active registrations. Short name: the full legal name is in the CSV. We merged spellings of the same company.
Medtronic tops the list with 297 registrations, 2.1% of the total: no holder dominates the device registry.
See the data
| Active registrations | |
|---|---|
| Medtronic | 297 |
| Boston Scientific | 208 |
| Nipro Medical | 181 |
| J&J MedTech | 173 |
| Becton Dickinson | 120 |
| KCI Colombia | 110 |
| Olympus | 91 |
| La Muela | 88 |
| Smith & Nephew | 85 |
| Madhos | 82 |
The ten holders with the most active reagent registrations
Number of active registrations. Short name: the full legal name is in the CSV. We merged spellings of the same company.
In reagents, two holders (Abbott and Annar Diagnóstica) account for one in five active registrations.
See the data
| Active registrations | |
|---|---|
| Abbott | 740 |
| Annar | 687 |
| Siemens | 371 |
| Quimiolab | 306 |
| Roche | 230 |
| Beckman Coulter | 219 |
| Ortho Clinical | 203 |
| Labcare | 186 |
| Thermo Fisher | 158 |
| Mindray | 143 |
Chapter 5 of 9
What is coming: 2,240 device registrations expire within two years
A medical device registration lasts 10 years, and renewal must be filed at least 3 months before it expires. The expiry date of each active registration shows what is coming: more than 1,100 device registrations expire every year from 2027 to 2031. We cover how to plan that filing in our guide to renewing your registration on time.1 2
Active registrations by year of expiry
Number of registrations. "Rest of 2026" runs from October 27 to December 31.
Device expiries rise every year, from 1,111 in 2027 to 1,681 in 2031.
See the data
| Medical devices | IVD reagents | |
|---|---|---|
| Rest of 2026 | 196 | 133 |
| 2027 | 1,111 | 809 |
| 2028 | 1,212 | 862 |
| 2029 | 1,392 | 909 |
| 2030 | 1,404 | 776 |
| 2031 | 1,681 | 944 |
- 1,045
- device registrations expire within the next 12 months
- 2,240
- device registrations expire within the next 24 months
- 827
- reagent registrations expire within the next 12 months
- 1,692
- reagent registrations expire within the next 24 months
Chapter 6 of 9
How many get renewed: fewer than three in ten
INVIMA gives a renewed registration a new number (with the suffix R1), and the dataset stops showing the original. The rate is therefore an estimate: we compare the renewals issued each year from 2021 to 2025 with the registrations that expired without renewal in those same years.1
Device registrations renewed at expiry, by risk class
Estimated share, expiries from 2021 to 2025.
The higher the risk, the more registrations get renewed: half of class III, against one in six in class I.
See the data
| Renewed | |
|---|---|
| Class I | 16.3% |
| Class IIa | 21.1% |
| Class IIb | 42.9% |
| Class III | 51.9% |
| All devices | 28.5% |
Many registrations are allowed to expire on purpose, because the product was discontinued or a new model came in under its own registration. But the data shows renewal is not automatic, and a product without an active registration cannot keep being sold in Colombia. Holders domiciled abroad renew more often than Colombian ones: 35.1% against 25.1%. For reagents the estimated rate is 42.9%, reaching 62.1% in category III.1
A registration that expires without renewal takes the product off the Colombian market while a new one is processed. Reviewing expiries a year ahead avoids that pause.
Chapter 7 of 9
New registrations: 2026 has nearly matched all of 2025
Medical device registrations issued by year
Number of registrations by the year in their number. 2026 runs to October 27.
With two months to go, 2026 has 1,229 new device registrations, 12 short of all of 2025.
See the data
| New registrations | Renewals | |
|---|---|---|
| 2017 | 1,147 | 169 |
| 2018 | 1,186 | 208 |
| 2019 | 1,258 | 265 |
| 2020 | 1,264 | 280 |
| 2021 | 1,396 | 396 |
| 2022 | 988 | 198 |
| 2023 | 1,119 | 206 |
| 2024 | 1,193 | 280 |
| 2025 | 1,241 | 356 |
| 2026 | 1,229 | 266 |
Since 2017 INVIMA has issued between 988 and 1,396 new device registrations a year: the low was 2022 and the high 2021. Device renewals went from 169 in 2017 to 356 in 2025.1
Chapter 8 of 9
What it means for manufacturers and importers
- Review your 2027 and 2028 expiries now. That is 2,323 device registrations. Renewal is filed at least 3 months ahead, and an expired registration means starting over.
- The risk class sets the filing. Almost seven in ten registered devices are class I or IIa, but class IIb and III require more evidence and are the ones renewed most.
- The registration can stay in the manufacturer's name. Three in ten device registrations are already held by a company based abroad: there is no need to hand the registration to your distributor.
- After registration comes technovigilance. Manufacturers and importers report adverse events and incidents to INVIMA for as long as the product is on the market.
For a manufacturer entering Colombia, the most important decision is whose name the registration is in. If it is in yours, you have control and the freedom to decide your regulatory and commercial future.
- INVIMA sanitary registrationThe filing step by step, with requirements, platforms and timelines.
- Medical devices in ColombiaWhat counts as a medical device, its classes and how it is registered.
- Risk classificationClass I, IIa, IIb and III: criteria and examples.
- TechnovigilanceWhat to report to INVIMA after launch, and by when.
- Regulatory consultingHow we handle registrations, renewals and technovigilance.
Chapter 9 of 9
Methodology, limits and how to cite
The source is the dataset "Registros sanitarios de dispositivos médicos y otras tecnologías" that INVIMA publishes on datos.gov.co, updated on October 16, 2026 and downloaded on October 27. It has 433,404 rows, one for each company or person with a role in a registration; we grouped them into 35,491 unique registrations.1
- Active is the status the dataset shows at the cutoff. Medical devices are the medical-surgical and dental groups; reagents are in vitro diagnostic reagents.
- Imported means a registration whose modality is to import and sell (or import and pack, semi-process or fill).
- Country of manufacturer: a registration counts once for each country among its manufacturers, so the percentages can add up to more than 100%.
- Holders: we merged spellings of the same company (punctuation or company type).
- Renewal: this is an estimate, because a renewed registration gets a new number and the original leaves the dataset. We compare renewals issued with registrations that expired without renewal, from 2021 to 2025.
- We do not measure approval times, because the dataset has no filing date, and we do not publish names of individuals.
Sources
- INVIMA, "Registros sanitarios de dispositivos médicos y otras tecnologías", datos.gov.co (updated October 16, 2026, accessed October 27, 2026, in Spanish).
- Decree 4725 of 2005, health registration, marketing authorization and surveillance regime for medical devices (INVIMA regulatory compilation, in Spanish).
- ProColombia, "Dispositivos médicos: Colombia tiene mercado y espacio para nueva inversión extranjera" (October 6, 2026, in Spanish).
Figures calculated by SPI Américas on INVIMA's open data as of October 27, 2026. The renewal rate is an estimate: see Methodology.
Let's talk
Do you have registrations expiring in 2027 or 2028?
We review your expiries, prepare renewals in time and register your new products with INVIMA. The first conversation is free.